SPEED CONTROL UNIT ESD 5500E
Sale!
80,00 €
Out of stock
Description
SPEED CONTROL UNIT ESD 5500E
The Generator Speed Controller ESD5500E Series Speed Control Unit is rugged enough to be placed in a control cabinet or engine mounted enclosure with other dedicated control equipment. If water, mist, or condensation may come in contact with controller, it should be mounted vertically. This will allow the fluid to drain away from the speed control unit.
TECHNICAL SPECIFICATIONS of ESD5500/ ESD5500E: | ||
Isochronous Operation/Steady State Stability | ± 0.25% or better | |
Speed Range/Governor | 1K-7.5K Hz continuous | |
Speed Drift with Temperature | ± 1% Maximun | |
IDLE Adjustment | 160 ± 20Hz ~ 60% of set speed | |
Droop adjustment Min.(K-L Jumpered) | 15Hz. ± 6Hz. per 1.0 A change | |
Droop adjustment Max.(K-L Jumpered) | 400Hz. ± 75Hz. per 1.0 A change | |
Droop Adj. Max. (K-L Jumpered) | 875Hz., ± 75Hz. per 1.0 A change | |
Droop Adj. Min. (K-L Jumpered) | 15Hz., ± 6Hz. per 1.0 A change | |
Speed Trim Range | ± 200Hz. | |
Remote Variable Speed Range | 500 -7.5Hz. or any part thereof | |
Terminal Sensitivity | J: 100Hz., ± 15Hz/Volt @ 5.0 K Impedance | |
L: 735Hz., ± 60Hz/Volt @ 65 K Impedance | ||
N: 148Hz., ± 10Hz/Volt @ 1Meg. Impedance | ||
P: 10V DC Provide @ 20ma Max. | ||
Speed Switch Adjustment Range | 1000-10000Hz. | |
ENVIRONMENTAL: | ||
Ambient Operating Temperature Range | -40°c to +85°c | |
Relative Humidity | up to 95% | |
Storage Temperature | -55°c ~ 90°c | |
Shock | 20-100HZ 500mm/Sec. | |
INPUT POWER: | ||
Provide | 12 or 24V DC Battery Systems(Transient and Reverse Voltage Protected) | |
Polarity | Negative Ground(Case Isolated) | |
Power Consumption | 50mA continuous plus actuator current | |
Actuator Current Range @ 25°c-(Inductive Load) | Min. 2.5 Amps, Max. 10 Amps continuous | |
Speed Sensor Signal | 0.5-120 V RMS | |
Speed Switch Relay Contacts(N.O.and N.C.) | 10Amp | |
PHYSICAL | ||
Weight | 650g |
Note: The performance parameters in the frequency when measuring 4000Hz